new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Jun 1

NERV++: An Enhanced Implicit Neural Video Representation

Neural fields, also known as implicit neural representations (INRs), have shown a remarkable capability of representing, generating, and manipulating various data types, allowing for continuous data reconstruction at a low memory footprint. Though promising, INRs applied to video compression still need to improve their rate-distortion performance by a large margin, and require a huge number of parameters and long training iterations to capture high-frequency details, limiting their wider applicability. Resolving this problem remains a quite challenging task, which would make INRs more accessible in compression tasks. We take a step towards resolving these shortcomings by introducing neural representations for videos NeRV++, an enhanced implicit neural video representation, as more straightforward yet effective enhancement over the original NeRV decoder architecture, featuring separable conv2d residual blocks (SCRBs) that sandwiches the upsampling block (UB), and a bilinear interpolation skip layer for improved feature representation. NeRV++ allows videos to be directly represented as a function approximated by a neural network, and significantly enhance the representation capacity beyond current INR-based video codecs. We evaluate our method on UVG, MCL JVC, and Bunny datasets, achieving competitive results for video compression with INRs. This achievement narrows the gap to autoencoder-based video coding, marking a significant stride in INR-based video compression research.

  • 3 authors
·
Feb 28, 2024

NerVE: Nonlinear Eigenspectrum Dynamics in LLM Feed-Forward Networks

We introduce NerVE, a unified eigenspectral framework for understanding how feed-forward networks (FFNs) in large language models (LLMs) organize and regulate information flow in high-dimensional latent space. Despite FFNs dominating the parameter budget, their high-dimensional dynamics remain poorly understood. NerVE addresses this gap through lightweight, memory-efficient tracking of eigenspectrum dynamics via four complementary metrics: Spectral Entropy (dispersion), Participation Ratio (effective dimensionality), Eigenvalue Early Enrichment (top-heaviness), and Jensen-Shannon divergence (distributional shifts). Our key insight is that FFN nonlinearities reinject variance across eigenmodes, fundamentally governing latent dimension utilization, and that optimizer geometry strongly modulates the extent of this variance reinjection. We validate NerVE across model scales, and diverse architectural and optimizer configurations, each uniquely shaping FFN dynamics: normalization schemes controlling variance flow; FFN weight geometries constraining latent space; positional encoding and activation functions regulating information flow; and optimizer choices redistributing effective capacity across depth. Across these settings, NerVE consistently recovers stable spectral signatures that correlate with model's generalization ability and respond predictably to design choices, generalizing beyond transformer to MLP-Mixer architectures, providing actionable insights for architectural and optimizer choices beyond trial-and-error.

Electroencephalography and Electromyography as a Non-Invasive Biomarker of Neural Regeneration: A Review of Central and Peripheral Nervous System Injury and Regeneration

Regeneration of the nervous system after injury remains an important therapeutic objective, especially in the central nervous system (CNS), in which regeneration is restricted by both neuronal limitations as well as adverse extracellular environments. Conversely, the peripheral nervous system (PNS) displays enhanced regenerative capability in the presence of supportive Schwann cells (SC) and pro-growth stimuli. While the structure and molecular mechanisms are thoroughly understood, functional biomarkers that can non-invasively monitor regeneration in real time are limited. In this review, we discuss the promise of electroencephalography (EEG) as well as electromyography (EMG) as real-time, non-invasive biomarkers to monitor damage to nerves and regeneration in both CNS and PNS contexts. First, we contrast biological and electrophysiological indicators of CNS/PNS injury, showing how EEG signs, including oscillatory power, connectivity, and evoked potential changes, reflect dysfunction due to injury as well as neuroplastic reorganization. Also, EMG provides direct insight into muscle activation and peripheral output, providing useful EEG complementation in neuromuscular pathway integrity and reactivation. In CNS injuries (e.g., stroke, spinal cord injury (SCI)), EEG typically shows global slowing, disrupted interhemispheric coherence, and partial recovery of higher frequencies. For PNS injuries, EEG can capture cortical remapping and return of somatosensory evoked responses with re-establishment of the peripheries' connectivity. EMG, in turn, enables monitoring of reinnervation and restoration of functional motor output. This review presents a dual-system perspective, positioning EEG and EMG not only as diagnostic tools but also as functional biomarkers of neural regeneration, thereby bridging electrophysiology, plasticity, and clinical recovery.

  • 4 authors
·
May 2

Raidionics: an open software for pre- and postoperative central nervous system tumor segmentation and standardized reporting

For patients suffering from central nervous system tumors, prognosis estimation, treatment decisions, and postoperative assessments are made from the analysis of a set of magnetic resonance (MR) scans. Currently, the lack of open tools for standardized and automatic tumor segmentation and generation of clinical reports, incorporating relevant tumor characteristics, leads to potential risks from inherent decisions' subjectivity. To tackle this problem, the proposed Raidionics open-source software has been developed, offering both a user-friendly graphical user interface and stable processing backend. The software includes preoperative segmentation models for each of the most common tumor types (i.e., glioblastomas, lower grade gliomas, meningiomas, and metastases), together with one early postoperative glioblastoma segmentation model. Preoperative segmentation performances were quite homogeneous across the four different brain tumor types, with an average Dice around 85% and patient-wise recall and precision around 95%. Postoperatively, performances were lower with an average Dice of 41%. Overall, the generation of a standardized clinical report, including the tumor segmentation and features computation, requires about ten minutes on a regular laptop. The proposed Raidionics software is the first open solution enabling an easy use of state-of-the-art segmentation models for all major tumor types, including preoperative and postsurgical standardized reports.

  • 7 authors
·
Apr 28, 2023

The Atacama Cosmology Telescope: DR6 Constraints on Extended Cosmological Models

We use new cosmic microwave background (CMB) primary temperature and polarization anisotropy measurements from the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) to test foundational assumptions of the standard cosmological model and set constraints on extensions to it. We derive constraints from the ACT DR6 power spectra alone, as well as in combination with legacy data from Planck. To break geometric degeneracies, we include ACT and Planck CMB lensing data and baryon acoustic oscillation data from DESI Year-1, and further add supernovae measurements from Pantheon+ for models that affect the late-time expansion history. We verify the near-scale-invariance (running of the spectral index d n_s/dln k = 0.0062 pm 0.0052) and adiabaticity of the primordial perturbations. Neutrino properties are consistent with Standard Model predictions: we find no evidence for new light, relativistic species that are free-streaming (N_{rm eff} = 2.86 pm 0.13, which combined with external BBN data becomes N_{rm eff} = 2.89 pm 0.11), for non-zero neutrino masses (sum m_nu < 0.082 eV at 95% CL), or for neutrino self-interactions. We also find no evidence for self-interacting dark radiation (N_{rm idr} < 0.134), early-universe variation of fundamental constants, early dark energy, primordial magnetic fields, or modified recombination. Our data are consistent with standard BBN, the FIRAS-inferred CMB temperature, a dark matter component that is collisionless and with only a small fraction allowed as axion-like particles, a cosmological constant, and the late-time growth rate predicted by general relativity. We find no statistically significant preference for a departure from the baseline LambdaCDM model. In general, models introduced to increase the Hubble constant or to decrease the amplitude of density fluctuations inferred from the primary CMB are not favored by our data.

  • 172 authors
·
Mar 18, 2025